JXSZ-1001-DOY Freshwater Dissolved Oxygen Electrode[Fluorescence Method] Sensor
Specifications
Product Name: Freshwater Dissolved Oxygen Sensor – Fluorescence Method
Sensor Type: Optical (Luminescent / Fluorescence-Based) Dissolved Oxygen Electrode
Measurement Principle: Quenching of luminescence by dissolved oxygen (fluorescence quenching method)
Medium: Freshwater (rivers, lakes, aquaculture tanks, etc.)
Non-consumptive measurement – no electrolyte, no membrane, no calibration drift
Maintenance-Free Operation – ideal for long-term field deployment
Measurement Parameters:
Measured Parameter: Dissolved Oxygen (DO)
DO Range: 0 – 20 mg/L (or 0 – 200% saturation)
Accuracy:±0.3 mg/L (0 – 10 mg/L range)
Resolution: 0.01 mg/L
Response Time (T90): 1 seconds
Stabilization Time: ~60 seconds
Temperature Measurement:
Temperature Range: 0°C to +35°C
Pressure Range: standard Atmospheric pressure
Optical Measurement Principle
Excitation Source: Blue LED (typically ~470 nm)
Detection Method: Red-shifted luminescence decay measurement
Interference Compensation: Built-in temperature compensation and ambient light shielding
No oxygen consumed during measurement
No need for electrolyte replacement or membrane cleaning
Electrical & Interface Specifications
Power Supply Voltage: 9V – 24V DC (typical: 12V DC)
Current Consumption: <50mA average
RS485 (Modbus RTU) – common for digital integration
Sensor Housing & Mechanical Features
Sensor Material:
Body: POM / PVC
Optical Cap: Replaceable fluorescent sensing cap
Protection Rating: IP68 (fully waterproof, submersible)
Dimensions:
- Length: ~190mm
- Diameter: ~25 – 35mm
Weight: ~250 – 400g (with cable)
Cable:
- Standard: 5m
- Waterproof and UV-resistant
- Custom lengths available
Environmental Conditions
Operating Temperature: 0°C to +50°C
Storage Temperature: -10°C to +60°C
Pressure Range: 0 – 3 bar (absolute pressure)
Flow Dependence: None (does not require stirring)
Biofouling Resistance: Optional anti-fouling protection (copper mesh, wipers, UV)
0-150mm 6inch Broad face Wire Rope Vernier Caliper
12v 300RPM GB37-520 Gear Motor
Kinco MT4000/MT5000 HMI and Mitsubishi FX PLC MT54-FX 3m Communication cable ![JXSZ-1001-DOY Freshwater Dissolved Oxygen Electrode[Fluorescence Method] Sensor](https://lk-tronics.com/wp-content/uploads/2025/07/LKSEN00100_Freshwater-Dissolved-Oxygen-ElectrodeFluorescence-Method-Sensor2.png)
![JXSZ-1001-DOY Freshwater Dissolved Oxygen Electrode[Fluorescence Method] Sensor - Image 2](https://lk-tronics.com/wp-content/uploads/2025/07/LKSEN00100_Freshwater-Dissolved-Oxygen-ElectrodeFluorescence-Method-Sensor1.png)
![JXSZ-1001-DOY Freshwater Dissolved Oxygen Electrode[Fluorescence Method] Sensor - Image 3](https://lk-tronics.com/wp-content/uploads/2025/07/LKSEN00100_Freshwater-Dissolved-Oxygen-ElectrodeFluorescence-Method-Sensor3.png)

![Human Body Temperature Sensor MAX30205 MTA [CJMCU 30205]](https://lk-tronics.com/wp-content/uploads/2021/10/Human-Body-Temperature-Sensor-MAX30205-MTA-CJMCU-302051-300x300.png)


There are no reviews yet.