MAX6675 Module + K Type Thermocouple Thermocouple Sensor
MAX6675 Module Specifications
- Temperature Range:
- Operating Range: 0°C to +1024°C (32°F to +1875°F)
- Accuracy: ±2°C (±4°F) typical, ±5°C (±9°F) maximum
- Resolution:
- 0.25°C (0.5°F)
- Interface:
- Communication: SPI (Serial Peripheral Interface)
- Pin Configuration:
- VCC: Power supply (3.3V to 5V)
- GND: Ground
- SCK: Serial Clock input
- MISO: Master In Slave Out (Data output)
- CS: Chip Select (Active Low)
- Power Requirements:
- Supply Voltage: 3.0V to 5.5V
- Current Consumption: 50 μA (in active mode); less than 1 μA in sleep mode
- Thermocouple Compatibility:
- Compatible with K-type thermocouples (chromel-alumel)
- Supports cold junction compensation to improve accuracy
- Features:
- Built-in Cold Junction Compensation: Automatically compensates for temperature differences at the connection point.
- Temperature Conversion Time: Approximately 100 ms
- Data Output: Digital output (SPI) allows easy integration with microcontrollers.
- Internal Filter: Reduces noise in the readings, ensuring stable output.
- Thermal Shutdown Protection: Built-in safety features to protect the device.
- Dimensions:
- Typical dimensions for the module: 38mm x 24mm (1.5in x 0.9in)
- Mounting holes for easy installation
- Environmental Conditions:
- Operating Temperature: -40°C to +125°C (-40°F to +257°F)
- Humidity: Non-condensing environments recommended
K-Type Thermocouple Specifications
- Material Composition:
- Positive Leg: Chromel (Nickel-Chromium alloy)
- Negative Leg: Alumel (Nickel-Aluminum alloy)
- Temperature Range:
- Standard range: -200°C to +1260°C (-328°F to +2300°F)
- Extended range with appropriate calibration: up to +1372°C (up to +2500°F)
- Response Time:
- Fast response due to small diameter wire (typically 0.5 mm or smaller)
- Insulation:
- Commonly insulated with materials like fiberglass, ceramic, or other high-temperature resistant materials.
- Form Factor:
- Available in various forms such as exposed junction, grounded junction, and ungrounded junction types.
Applications
- Industrial temperature monitoring
- HVAC systems
- Food processing
- Chemical processing
- Laboratory research
Example Wiring Diagram
- Connect the K-type thermocouple to the MAX6675 module.
- Connect the module to a microcontroller (like Arduino) using SPI communication pins.