Specifications
- Product Type: Ultrasonic distance measuring sensor
- Model Type: RS485 industrial ultrasonic sensor
- Application: Distance measurement and level detection
Measurement Parameters
- Measuring Range: 0.3 m to 7.5 m (750 cm)
- Resolution: typically 1 cm
- Accuracy: ±1% (depends on target surface and environment)
- Blind Zone: approximately 20 cm to 30 cm (near-field dead zone)
Electrical Characteristics
- Power Supply: 10 V DC to 30 V DC
- Power Consumption: low power (typically < 1 W)
- Output Signal: RS485 differential signal
- Communication Protocol: Modbus RTU
Communication
- Interface: RS485
- Baud Rate: typically 9600 bps (configurable in some versions)
- Data Format: 8N1 standard Modbus format
- Device Address: configurable (multi-sensor network support)
Sensing Principle
- Technology: Ultrasonic pulse echo method
- Measurement Method: Time-of-flight (TOF) calculation
- Target Requirement: solid or liquid reflective surface
Mechanical Characteristics
- Housing Material: industrial-grade ABS or metal housing (model dependent)
- Protection Rating: IP65 to IP67 (dust and water resistant)
- Mounting Type: threaded or bracket mounting
- Sensor Head: waterproof ultrasonic transducer
Environmental
- Operating Temperature: -20°C to +70°C
- Storage Temperature: -30°C to +80°C
- Humidity: up to 95% RH (non-condensing)
Performance
- Stable long-range distance measurement up to 7.5 m
- High resistance to dust, fog, and humidity compared to optical sensors
- Suitable for outdoor and industrial environments
Applications
- Water tank level measurement
- Industrial automation systems
- Wastewater level monitoring
- Material level detection in silos
- Smart irrigation systems
Important Notes
- Soft surfaces (foam, cloth) may reduce measurement accuracy
- Ensure correct alignment with the target surface for the best results
- Avoid strong airflow or turbulence near the sensor face
- RS485 wiring should be shielded for industrial noise immunity
- Proper Modbus configuration (ID, baud rate) is required before operation