owMr 2400Watt DC 24V AC 220V All In One Solar Inverter Charger POW-HVM2.4H-24V
INTRODUCTION
This is a multi-function all in one inverter charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support with portable size.
Its comprehensive as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Features
- Pure sine wave 24V inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart AC is recovering
- Overload/ Over temperature/ short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- WIFI/GPRS(Option)
- Can connect to lithium battery
Data Sheet
| INVERTER MODEL | 1.5KW 12V | 2.4KW 24V |
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); | |
| 100Vac±7V (Appliances) | ||
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz/ 60Hz (Auto-detection) | |
| Low Loss Frequency | 40±lHz | |
| Low Loss Return Frequency | 42±lHz | |
| High Loss Frequency | 65±lHz | |
| High Loss Return Frequency | 63±lHz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | |
| Transfer Time | 10ms typical (UPS); | |
| 20ms typical (Appliances) | ||
| INVERTER MODEL | 1.5KW 12V | 2.4KW 24V |
| Rated Output Power | 1.5KW | 2.4KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 91% | |
| Overload Protection | 5s@ >150% Io ad; 10s@ 110% ~ 150% Io ad | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 12Vdc | 24Vdc |
| Cold Start Voltage | 11.5Vdc | 23.0Vdc |
| Low DC Warning Voltage | 11.0Vdc | 22.0Vdc |
| @ Io ad < 50>% | 10.5Vdc | 21.0Vdc |
| @ load >50% | ||
| Low DC Warning Return Voltage | 11.5Vdc | 22.5Vdc |
| @ load < 50% | 11.0Vdc | 22.0Vdc |
| @ load >50% | ||
| Low DC Cut off Voltage | 10.2Vdc | 20.5Vdc |
| @ load < 50% | 9.6Vdc | 20.0Vdc |
| @ load >50% | ||
| High DC Recovery Voltage | 14.0Vdc | 32Vdc |
| High DC Cut-off Voltage | 16.0Vdc | 33Vdc |
| No Load Power Consumption | <25W | <30W |
| Utility Charging Mode | ||
| INVERTER MODEL | 1.5KW 12V | 2.4KW 24V |
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 60 Amp | |
| Bulk Charging Voltage | ||
| Flooded Battery | 14.6 | 29.2 |
| AGM / Gel Battery | 14.1 | 28.2 |
| Floating Charging Voltage | 13.5Vdc | 27.0Vdc |
| MPPT Solar Charging Mode | ||
| INVERTER MODEL | 1.5KW 12V | 2.4KW 24V |
| Max. PV Array Power | 2000W | 3000W |
| Nominal PV Voltage | 240Vdc | 240Vdc |
| PV Array MPPT Voltage Range | 90~430Vdc | 90~430Vdc |
| Max. PV Array Open Circuit Voltage | 450Vdc | 450Vdc |
| Max Charging Current (AC charger plus solar charger) | 80Amp | 80Amp |
| INVERTER MODEL | 1.5KW 12V | 2.4KW 24V |
| Safety Certification | CE | |
| Operating Temperature Range | -10°Cto50°C | |
| Storage temperature | -15°C~ 60° C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W* H), mm | 348X270X95 | |
| Net Weight, kg | 4 | 5 |
VISIT OUR FACEBOOK PAGE FOR MORE INFO | MORE PRODUCT IN OUR SHOP







There are no reviews yet.