-21%
Sensors

MAX6675 Module with K Type Thermocouple

Availability:

In stock


LKSEN00075

Rs.630.00 Rs.800.00

In stock

or 3 X Rs. 210.00 with Koko Koko
Compare

MAX6675 Module + K Type Thermocouple Thermocouple Sensor

 

MAX6675 Module Specifications

  1. Temperature Range:
    • Operating Range: 0°C to +1024°C (32°F to +1875°F)
    • Accuracy: ±2°C (±4°F) typical, ±5°C (±9°F) maximum
  2. Resolution:
    • 0.25°C (0.5°F)
  3. Interface:
    • Communication: SPI (Serial Peripheral Interface)
    • Pin Configuration:
      • VCC: Power supply (3.3V to 5V)
      • GND: Ground
      • SCK: Serial Clock input
      • MISO: Master In Slave Out (Data output)
      • CS: Chip Select (Active Low)
  4. Power Requirements:
    • Supply Voltage: 3.0V to 5.5V
    • Current Consumption: 50 μA (in active mode); less than 1 μA in sleep mode
  5. Thermocouple Compatibility:
    • Compatible with K-type thermocouples (chromel-alumel)
    • Supports cold junction compensation to improve accuracy
  6. Features:
    • Built-in Cold Junction Compensation: Automatically compensates for temperature differences at the connection point.
    • Temperature Conversion Time: Approximately 100 ms
    • Data Output: Digital output (SPI) allows easy integration with microcontrollers.
    • Internal Filter: Reduces noise in the readings, ensuring stable output.
    • Thermal Shutdown Protection: Built-in safety features to protect the device.
  7. Dimensions:
    • Typical dimensions for the module: 38mm x 24mm (1.5in x 0.9in)
    • Mounting holes for easy installation
  8. Environmental Conditions:
    • Operating Temperature: -40°C to +125°C (-40°F to +257°F)
    • Humidity: Non-condensing environments recommended

K-Type Thermocouple Specifications

  1. Material Composition:
    • Positive Leg: Chromel (Nickel-Chromium alloy)
    • Negative Leg: Alumel (Nickel-Aluminum alloy)
  2. Temperature Range:
    • Standard range: -200°C to +1260°C (-328°F to +2300°F)
    • Extended range with appropriate calibration: up to +1372°C (up to +2500°F)
  3. Response Time:
    • Fast response due to small diameter wire (typically 0.5 mm or smaller)
  4. Insulation:
    • Commonly insulated with materials like fiberglass, ceramic, or other high-temperature resistant materials.
  5. Form Factor:
    • Available in various forms such as exposed junction, grounded junction, and ungrounded junction types.

Applications

  • Industrial temperature monitoring
  • HVAC systems
  • Food processing
  • Chemical processing
  • Laboratory research

Example Wiring Diagram

  • Connect the K-type thermocouple to the MAX6675 module.
  • Connect the module to a microcontroller (like Arduino) using SPI communication pins.