Buy Extension board for RS-485 communication FX3U-485-BD
- Manufacturer : Mitsubishi Electric
- FX3U-485-BD
- Extension board for RS – 485 communication FX3U – 485 – BD
- Transmission standard : RS-485 standard, RS-422 standard compliant
- Insulation method : Non-insulated (communication line and CPU)
- Transmission distance : Maximum 50 m
- External device connection method : European type terminal block
- Communication method : Half duplex bi-directional
- Communication procedure : No protocol, computer link (dedicated protocol format 1, dedicated protocol type 4), parallel link, simple PC link, inverter communication
- communication speed No procedure, computer link : 300/600/1200/2400/4800/9600/19200 (bps)
- Parallel link : 115200 (bps)
- Simple PC link : 38400 (bps)
- Inverter communication : 4800/9600/19200 (bps)
- Display (LED) : RD, SD
- Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)
- Application sequencer : FX3U, FX3UC-32MT-LT (-2)
- Power supply : DC 5 V 40 mA (internal power supply from the sequencer)
- Ambient temperature : 0 to 55 ° C. … Operating, -25 to 75 ° C. ….. Save
- Relative humidity : 5 to 95% RH (noncondensing)…. in operation
- Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
- Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
- Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
- Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
- Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
- Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
- tor with period of 30 to 100 Hz
- Withstand voltage : Non-insulated between communication line and PLC main unit (Do not perform withstand voltage test)
- Insulation resistance : Non-insulated between the communication line and the programmable controller (Do not conduct insulation resistance test)
- Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
- Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
- Shipping Weight : 2 Kg
VISIT OUR FACEBOOK PAGE FOR MORE INFO | MORE PRODUCT IN OUR SHOP
There are no reviews yet.