12V Power Adapter DC 4000mA MYX-1204000E
INTRODUCTION
- • 12V Power Adapter Very low standby power achieved
- • Reliability level or 10000 hours MTBF& 0.5% annual field failure rate@25℃
INPUT REQUIREMENTS
-
- • AC Input voltage rating 100Vac to 240Vac
- • AC Input voltage range 90Vac to 264Vac
- • AC Input frequency range 47Hz to 63Hz
- • Max. In-rush current 30A for 100Vac at full load<75A for 240Vac at full load
- • Input current 1.5A Max @ 90V/60Hz full load
- • Standby power 0.3W Max @ 230V/50Hz no load
OUTPUT REQUIREMENTS
-
- • Output voltage +12V
- • Output voltage tolerance +/-0.5V%
- • Min load current 0 mA
- • Max load current 5000 mA
- • Line regulation +/-1%
- • load regulation +/-0.5
- • Ripple & Noise 300mVp-p (max)
DC-20MHz/Ripple and Noise is measured on output connector with 20MHz oscilloscope
bandwidth differentially with a 10uF electrolytic and 0.1uF ceramic capacitors across output
- • Total output power 60W typical
- • Efficiency 86% min@115~230Vac50/60Hz with full load
- • Hold up time 10 sec.min.@ 100Vac/60Hz with full load
- • Turn on delay time 3sec.max.@ 100Vac/60Hz with full load
- • Switching frequency 65K Hz typical
PROTECTION FUATURES
- • Over-voltage protection Output shut down (Auto recovery) When output voltage exceeds
- • Over-current protection Output shut down (Auto recovery) When output current exceeds
- • Short circuit protection Output shut down (Auto restart)
ENVIRONMENTAL
- • Operation temperature -20℃ to +40℃
- • Operation humidity 20% to 90% R.H.
- • Storage temperature -20℃ to +75℃
- • Storage humidity 0% to 90% R.H.
SAFETY REQUIREMENTS AND CERTIFICATION
Regulatory Standard
The power supply shall comply the following international regulatory standards
Dielectric withstand (Hi-pot) test
• Input to output 3000Vac 10mA /60S
Insulation
• Input to output DC 500V 10M ohm Min