I/O expansion unit FX2N-32ER-ES/UL | LK Tronics https://lk-tronics.com/product-tag/i-o-expansion-unit-fx2n-32er-es-ul/ Components for the Future Wed, 13 Sep 2023 17:23:02 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 https://i0.wp.com/lk-tronics.com/wp-content/uploads/2023/11/cropped-Main-Logo-lktronics-2023-512-x-512-px-1.png?fit=32%2C32&ssl=1 I/O expansion unit FX2N-32ER-ES/UL | LK Tronics https://lk-tronics.com/product-tag/i-o-expansion-unit-fx2n-32er-es-ul/ 32 32 153475254 I/O expansion unit FX2N-32ER-ES/UL https://lk-tronics.com/product/i-o-expansion-unit-fx2n-32er-es-ul/ https://lk-tronics.com/product/i-o-expansion-unit-fx2n-32er-es-ul/#respond Sun, 05 Jun 2022 06:28:53 +0000 https://lk-tronics.com/?post_type=product&p=9243 LK Tronics
I/O expansion unit FX2N-32ER-ES/UL

මෙම අයිතමය අපගේ වෙබ් අඩවියෙහි Shipping from Overseas
සේවාව යටතේ ගෙන්වන බැවින් මෙය ඔබ හට ලැබීමට
වැඩ කරන දින 10 – 20 පමණ ගත වේ.
මෙම අයිතමය ඔබ ඇනවුම් කල පසු මෙහි සියලුම යාවත් කාලීන කටයුතු e-mail මගින් සිදු කෙරේ
ස්තූතියි!

I/O expansion unit FX2N-32ER-ES/UL
lahiru Dhananjaya

]]>
LK Tronics
I/O expansion unit FX2N-32ER-ES/UL

I/O expansion unit FX2N-32ER-ES/UL

  • Manufacturer : Mitsubishi Electric
  • FX2N-32ER-ES/UL
  • I / O expansion unit FX2N – 32ER – ES / UL
  • Application sequencer : FX1N, FX3G, FX2N, FX3U
  • mass : 0.65 Kg
  • Rated voltage : AC 100 V to 240 V
  • Voltage tolerance range : AC 85V ~ 264V
  • Rated frequency : 50/60 Hz
  • Power supply fuse : 250 V 3.15 A (3A)
  • Inrush current : AC 100 V: maximum 40 A 5 ms or less AC 200 V: maximum 60 A 5 ms or less
  • power consumption : 30 W
  • 24 VDC service power supply : 24 VDC 250 mA or less When input / output expansion block is connected, 24 VDC service power is consumed.
  • Input specification :
  • Number of input points : 16 points
  • Input connection shape : Removable terminal block (M3 screw)
  • Input format : Sink / source
  • Input signal voltage : DC 24 V ± 10%
  • Input impedance : 4.3 kΩ
  • Input signal current : 5 mA / 24 VDC
  • Input ON sensitivity current : 3.5 mA or more
  • Input OFF sensitivity current : 1.5 mA or less
  • Input response time : About 10 ms
  • Input signal format : Sink: no-voltage contact input or NPN open collector transistor source: no-voltage contact input or PNP open collector transistor
  • Input circuit insulation : Photocoupler insulation
  • Input operation display : LED on the panel when input is ON
  • Number of output points : 16 points
  • Output connection shape : Removable terminal block (M3 screw)
  • Output type / format : relay
  • External power supply : DC 30 V or less AC 240 V or less (When not compliant with CE, UL, cUL standard, AC 250 V or less)
  • Maximum load Resistive load : Please set the total load current per 2A / 1 point common as follows. . Output 4 points / common: 8 A or less
  • Inductive load : 80VA
  • Minimum load : DC 5 V 2 mA (reference value)
  • Response time OFF → ON : About 10 ms
  • ON → OFF : About 10 ms
  • Circuit insulation : Mechanical insulation
  • Output operation indication : LED lit when relay coil is energized
  • Ambient temperature : 0 to 55 ° C. … Operating -25 to 75 ° C. ….. Save
  • Relative humidity : 5 to 95% RH (noncondensing)…. in operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2
  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
  • Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
  • tor with period of 30 to 100 Hz
  • Withstand voltage : Between the power supply terminal (AC power supply) and the earth terminal: AC 1500 V for 1 minute 24 VDC Service power supply and between the input terminal (24 VDC) and the earth terminal: 500 V AC for 1 minute Between the output terminal (relay)
  • Insulation resistance : Between each terminal and earth terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter
  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.
  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight : 1.7 Kg