Application

The Cooper suntree three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with IEC 60364-7-712. Includes a five year limited warranty.

These pre-wired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant `l circuit prevents damage to the surge protective devices.

The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication,the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.

Dimension

 

Surge Protective Device Dimension

 

Short-Circuit Interrupting (SCI) Technology

 

(SCI) Technology

 

 

Specifications

SUP2H-PV series surge protector SUP2H1-PV SUP2H1-PV SUP2-PV
UCPV(VDC) 1000V 1200V 1500V
Max system discharge current (8/20μs)Imax 40KA 40KA 40KA
Voltage Protection level(up) ≤4.0KV ≤4.5KV ≤4.5KV
Voltage Protection level at 5kA(up) ≤3.6KV ≤4.0KV ≤5.0KV
Integrated Fuse breaking capacity/interrupting rating 40KA/1000vdc 40KA/1200vdc 40KA/1500vdc
technology Short-Circuit interruption (SCI)overcurrent protection
Operating temperature range(TU) -40℃ to +80℃
Nominal discharge current (8/20 μs){(DC+/DC-)>PE}(In) 20KA
Response time (A) <25ns
Operating State/Fault indication Green (good)/RED(repiace)
Conductor rating and cross-sectional Area Minimum 60/75℃ 1.5mm2/14AWG solid/flexible
Maximum 60/75℃ 35mm2/2AWG stranded/25mm2/4AWG flexible
Mounting 35mm DIN rall per EN 60715
Enclosure material UL 90VO thermopiastic
Degree of Protection IP20
Capacity 3 Modules,DIN 43880
Standards information IEC 61643-31 Type2,IEC 61643-1 ClassⅡ
product Warranty Five Years

Remote Contact signaling​

Remote Contact signaling Type Changeover contact
AC switching capacity(volts/Amps) 250V/0.1A
DC switching capacity(volts/Amps) 250V/0.1A;125V/0.2A;75V/0.5A
Conductor ratings and cross-sectional area for remote
Contact signal terminals
60/75℃Max,1.5mm2/14AWG solid/flexible
Ordering Order from Catalog numbers Above

 

Typical Application Schematics

 

 Schematics

Does not apply to 1200Vdc
1.Use a suitable electrical insulator to keep a 10mm min.safety distance from the PV-SPD and other grounfed parts in the housing.
2.No metal covers are in the area of the module release as shown.

 