4000mA | LK Tronics https://lk-tronics.com/product-tag/4000ma/ Components for the Future Fri, 29 Dec 2023 17:26:34 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 https://i0.wp.com/lk-tronics.com/wp-content/uploads/2023/11/cropped-Main-Logo-lktronics-2023-512-x-512-px-1.png?fit=32%2C32&ssl=1 4000mA | LK Tronics https://lk-tronics.com/product-tag/4000ma/ 32 32 153475254 Power Adapter DC12V 4000mA MYX-1204000E https://lk-tronics.com/product/power-adapter-dc12v-4000ma-myx-1204000e/ https://lk-tronics.com/product/power-adapter-dc12v-4000ma-myx-1204000e/#respond Wed, 16 Nov 2022 12:07:45 +0000 https://lk-tronics.com/?post_type=product&p=10745 LK Tronics
Power Adapter DC12V 4000mA MYX-1204000E

LKELEC00029

Short info:

  • Output voltage +12V
  • Output voltage tolerance +/-0.5V%
  • Min load current 0 mA

Power Adapter DC12V 4000mA MYX-1204000E
lahiru Dhananjaya

]]>
LK Tronics
Power Adapter DC12V 4000mA MYX-1204000E

12V Power Adapter DC 4000mA MYX-1204000E

INTRODUCTION

  • •  12V Power Adapter Very low standby power achieved
  • • Reliability level or 10000 hours MTBF& 0.5% annual field failure rate@25℃

INPUT REQUIREMENTS

    • • AC Input voltage rating 100Vac to 240Vac
    • • AC Input voltage range 90Vac to 264Vac
    • • AC Input frequency range 47Hz to 63Hz
    • • Max. In-rush current 30A for 100Vac at full load<75A for 240Vac at full load
    • • Input current 1.5A Max @ 90V/60Hz full load
    • • Standby power 0.3W Max @ 230V/50Hz no load

OUTPUT REQUIREMENTS

    • • Output voltage +12V
    • • Output voltage tolerance +/-0.5V%
    • • Min load current 0 mA
    • • Max load current 5000 mA
    • • Line regulation +/-1%
    • • load regulation +/-0.5
    • • Ripple & Noise 300mVp-p (max)

DC-20MHz/Ripple and Noise is measured on output connector with 20MHz oscilloscope
bandwidth differentially with a 10uF electrolytic and 0.1uF ceramic capacitors across output

  • • Total output power 60W typical
  • • Efficiency 86% min@115~230Vac50/60Hz with full load
  • • Hold up time 10 sec.min.@ 100Vac/60Hz with full load
  • • Turn on delay time 3sec.max.@ 100Vac/60Hz with full load
  • • Switching frequency 65K Hz typical

PROTECTION FUATURES

  • • Over-voltage protection Output shut down (Auto recovery) When output voltage exceeds
  • • Over-current protection Output shut down (Auto recovery) When output current exceeds
  • • Short circuit protection Output shut down (Auto restart)

ENVIRONMENTAL

  • • Operation temperature -20℃ to +40℃
  • • Operation humidity 20% to 90% R.H.
  • • Storage temperature -20℃ to +75℃
  • • Storage humidity 0% to 90% R.H.

SAFETY REQUIREMENTS AND CERTIFICATION

Regulatory Standard
The power supply shall comply the following international regulatory standards
Dielectric withstand (Hi-pot) test
• Input to output 3000Vac 10mA /60S
Insulation
• Input to output DC 500V 10M ohm Min

VISIT OUR FACEBOOK PAGE FOR MORE INFO | MORE PRODUCT IN OUR SHOP

Power Adapter DC12V 4000mA MYX-1204000E
lahiru Dhananjaya

]]>
https://lk-tronics.com/product/power-adapter-dc12v-4000ma-myx-1204000e/feed/ 0 10745