24V DC Output 220V AC 3000Watt | LK Tronics https://lk-tronics.com/product-tag/24v-dc-output-220v-ac-3000watt/ Components for the Future Mon, 04 Sep 2023 17:12:08 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 https://i0.wp.com/lk-tronics.com/wp-content/uploads/2023/11/cropped-Main-Logo-lktronics-2023-512-x-512-px-1.png?fit=32%2C32&ssl=1 24V DC Output 220V AC 3000Watt | LK Tronics https://lk-tronics.com/product-tag/24v-dc-output-220v-ac-3000watt/ 32 32 153475254 PowMr 3000Watt Solar Inverter Charger 24V DC Output 220V AC  https://lk-tronics.com/product/powmr-24v-dc-output-220v-ac-3000watt-solar-inverter-charger/ https://lk-tronics.com/product/powmr-24v-dc-output-220v-ac-3000watt-solar-inverter-charger/#respond Tue, 26 Apr 2022 18:14:30 +0000 https://lk-tronics.com/?post_type=product&p=9020 LK Tronics
PowMr 3000Watt Solar Inverter Charger 24V DC Output 220V AC 

මෙම අයිතමය අපගේ වෙබ් අඩවියෙහි Shipping from Overseas
සේවාව යටතේ ගෙන්වන බැවින් මෙය ඔබ හට ලැබීමට
වැඩ කරන දින 10 – 20 පමණ ගත වේ.
මෙම අයිතමය ඔබ ඇනවුම් කල පසු මෙහි සියලුම යාවත් කාලීන කටයුතු e-mail මගින් සිදු කෙරේ
ස්තූතියි!

PowMr 3000Watt Solar Inverter Charger 24V DC Output 220V AC 
lahiru Dhananjaya

]]>
LK Tronics
PowMr 3000Watt Solar Inverter Charger 24V DC Output 220V AC 

PowMr 3000Watt Solar Inverter Charger 24V DC Output 220V AC 

SPECIFICATIONS

Table 1 Line Mode Specifications

INVERTER MODEL 1KVA 2KVA 3KVA 3KVA Plus 5KVA
Input Voltage Waveform Sinusoidal (utility or generator)
Nominal Input Voltage

230Vac

Low Loss Voltage

170Vac±7V (UPS);
90Vac±7V (Appliances)

Low Loss Return Voltage

180Vac±7V (UPS);
100Vac±7V (Appliances)

High Loss Voltage

280Vac±7V

High Loss Return Voltage

270Vac±7V

Max AC Input Voltage

300Vac

Nominal Input Frequency 50Hz / 60Hz (Auto detection)
Low Loss Frequency

40±1Hz

Low Loss Return Frequency

42±1Hz

High Loss Frequency

65±1Hz

High Loss Return Frequency

63±1Hz

Output Short Circuit Protection

Circuit Breaker

Efficiency (Line Mode) >95% ( Rated R load, battery full charged )
Transfer Time 10ms typical (UPS); 20ms typical (Appliances)
When AC input voltage drops to 170V, the output power will be derated.

Table 2 Inverter Mode Specifications

INVERTER MODEL 1KVA 2KVA 3KVA 3KVA Plus 5KVA
Rated Output Power 1KVA/1KW 2KVA/2KW 3KVA/3KW 5KVA/5KW
Output Voltage Waveform

Pure Sine Wave

Output Voltage Regulation

230Vac±5%

Output Frequency

50Hz

Peak Efficiency

93%

Overload Protection 5s@≥150% load; 10s@105%~150% load
Surge Capacity

2* rated power for 5 seconds

Nominal DC Input Voltage 12Vdc 24Vdc

24Vdc

48Vdc
Cold Start Voltage 11.5Vdc 23.0Vdc

23.0Vdc

46.0Vdc
Low DC Warning Voltage
@ load < 50%
@ load ≥ 50%

23.0Vdc
22.0Vdc

46.0Vdc
44.0Vdc
11.5Vdc
11.0Vdc
23.0Vdc
22.0Vdc
Low DC Warning Return Voltage
@ load < 50%
@ load ≥ 50%

23.5Vdc
23.0Vdc

47.0Vdc
46.0Vdc
11.7Vdc
11.5Vdc
23.5Vdc
23.0Vdc
Low DC Cut-off Voltage
@ load < 50%
@ load ≥ 50%

21.5Vdc
21.0Vdc

43.0Vdc
42.0Vdc
10.7Vdc
10.5Vdc
21.5Vdc
21.0Vdc
High DC Recovery Voltage 15Vdc 30Vdc

32Vdc

62Vdc
High DC Cut-off Voltage 16Vdc 31Vdc

33Vdc

63Vdc
No Load Power Consumption

<25W

<55W

Table 3 Charge Mode Specifications

Table 4 General Specifications

INVERTER MODEL

1KVA

2KVA 3KVA 3KVA Plus 5KVA
Safety Certification

CE

Operating Temperature Range

-10°C to 50°C

Storage temperature

-15°C~ 60°C

Humidity

5% to 95% Relative Humidity (Non-condensing)

Dimension (D*W*H), mm 88 x 225 x 320 100 x 285 x 334 100 x 300 x 440
Net Weight, kg (PWM model)

5.0

5.5

6.3

8.5
Net Weight, kg (MPPT model)

6.5

9.5

9.7

Features:

  1. 220V Pure sine wave inverter
  2. Compatible to mains voltage or generator power
  3. Auto restart and AC is recovering.
  4. Smart battery charger design for optimized battery performance
  5. Cold start function
  6. For 24V Lead-acid battery
  7. Protection:
  • Overload/ Over temperature/ short circuit protection

3000w charging modes

Built-in 40A MPPT CONTROLLER 3KVA/3KW Inverter Mode Specifications

  • Rated Output Power 3KVA/3KW
  • Peak Efficiency 93>#/span###
  • Output Voltage Waveform Pure Sine Wave
  • Output Voltage Regulation 230Vac±5>#/span###
  • Output Frequency 50Hz
  • Surge Capacity 2* rated power for 5 seconds
  • Overload Protection 5s@≥150% load; 10s@105%~150% load
  • Nominal DC Input Voltage 24Vdc
  • Cold Start Voltage 23.0Vdc

3KW 40A MPPT Controller Inverter General Specifications

  • Operating Temperature Range -10°C to 50°C Storage temperature -15°C~ 60°C
  • Humidity 5% to 95% Relative Humidity (Non-condensing)
  • Dimension (D*W*H), mm 100 x 285 x 334 Net Weight, kg 8.2
  • Recommended battery cable size: 1 x 2AWG Cable (mm2) 35 Torque value(max) 2 Nm
  • PV Connection
  • 1. Open circuit Voltage (Voc) of PV modules not exceed the max. PV array open-circuit voltage of the inverter.
  • Max. PV Array Open Circuit Voltage 102Vdc PV Array MPPT Voltage Range 30~80Vdc

24V Inverter Charge Mode Specifications

  • Utility Charging Mode
  • INVERTER MODEL 3KVA Charging Algorithm 3-Step AC Charging Current (Max) 25Amp (@VI/P=230Vac)
  • Bulk Charging Voltage: Flooded Battery 29.2 AGM / Gel Battery 28.2
  • Floating Charging Voltage 27Vdc
  • MPPT Solar Charging Mode
  • Charging Current 40Amp PV Array MPPT Voltage Range Max 30~80Vdc
  • PV Array Open Circuit Voltage Max 102Vdc
  • Charging Current(AC charger plus solar charger) 60Amp

 

Package:

  • 3000W Solar Inverter x 1
  • Communication cable x 1
  • Software CD x 1
  • DC Fuse x 1
  • Ring terminal x 1
  • Strain relief plate x 2
  • Screws x 4

VISIT OUR FACEBOOK PAGE FOR MORE INFO | MORE PRODUCT IN OUR SHOP

PowMr 3000Watt Solar Inverter Charger 24V DC Output 220V AC 
lahiru Dhananjaya

]]>
https://lk-tronics.com/product/powmr-24v-dc-output-220v-ac-3000watt-solar-inverter-charger/feed/ 0 9020